Proline Promag 50H, 53H
Endress+Hauser 43
Coupling SC DIN 11851,
threaded adapter
1.4404 (316L)
Sensor
DN
Fits to piping di G L H × B
5*H**-2*********** [mm] EN 10357
(DIN 11850)
[mm] [mm] [mm] [mm]
A0005553
2 to 8 Tube 12 × 1
(DN 10)
10 Rd 28 × ¹⁄" 44 62 × 42
15 Tube 18 × 1.5
(DN 15)
16 Rd 34 × ¹⁄" 44 62 × 42
25 (DIN) Tube 28 × 1
or 28 × 1.5
(DN 25)
26 Rd 52 × 1/6" 52 72 × 55
• Fitting length = (2 × L) + 86 mm
• Surface roughness: R
a
0.8 m
• If pigs are used for cleaning, it is essential to take the inside diameters
of measuring tube and process connection (di) into account!
Coupling DIN 11864-1, aseptic
threaded hygienic connection,
form A
1.4404 (316L)
Sensor
DN
Fits to piping di G L H × B
5*H**-3*********** [mm] EN 10357
(DIN 11850)
[mm] [mm] [mm] [mm]
A0005558
2 to 8 Tube 13 × 1.5
(DN 10)
10 Rd 28 × ¹⁄" 42 62 × 42
15 Tube 19 × 1.5
(DN 15)
16 Rd 34 × ¹⁄" 42 62 × 42
25 (DIN) Tube 29 × 1.5
(DN 25)
26 Rd 52 × 1/6" 49 72 × 55
• Fitting length = (2 × L) + 86 mm
• Surface roughness: R
a
0.8 m
• If pigs are used for cleaning, it is essential to take the inside diameters
of measuring tube and process connection (di) into account!
Flange according to DIN 11864-2,
aseptic grooved flange, form A
1.4404 (316L)
Sensor
DN
Fits to piping di G L LK M H × B
5*H**-4*********** [mm] EN 10357
(DIN 11850)
[mm] [mm] [mm] [mm] [mm] [mm]
A0005559
2 to 8 Tube 13 × 1.5
(DN 10)
10 54 48.5 37 9 62 × 42
15 Tube 19 × 1.5
(DN 15)
16 59 48.5 42 9 62 × 42
25 (DIN) Tube 29 × 1.5
(DN 25)
26 70 48.5 53 9 72 × 55
• Fitting length = (2 × L) + 86 mm
• Surface roughness: R
a
0.8 m
• If pigs are used for cleaning, it is essential to take the inside diameters
of measuring tube and process connection (di) into account!