Proline Promag 50H, 53H
54 Endress+Hauser
Tri-Clamp for L14 AM7
1.4404 (F316L)
Sensor
DN
Fits to piping di G D L LK L
tot
1)
[mm] [inch] ASME BPE [mm] [mm] [mm] [mm] [mm] [mm]
A0005543
Order codes: 5*H**-1***********, DKH**-HE**
Surface roughness: R
a
0.8 m
40 1½" 38.1 × 1.65 34.8 50.4 92.0 68.6 71.0 273.2
50 2" 50.8 × 1.65 47.5 63.9 105.0 68.6 83.5 273.2
65 – 63.5 × 1.65 60.2 77.4 121.0 68.6 100.0 273.2
80 3" 76.2 × 1.65 72.9 90.9 140.7 99.6 114.0 333.2
100 4" 101.6 × 2.11 97.4 118.9 166.7 99.6 141.0 333.2
150 6" 152.4 × 2.77 146.9 166.9 226.7 53 200.0 300
Order codes: 5*H**-1***********+CA/+CB, DKH**-HE**+CA/+CB
Surface roughness +CA: R
a
0.8 m
Surface roughness +CB: R
a
0.38 m
40 1½" 38.1 × 1.65 34.8 50.4 99.7 43 71.0 220
50 2" 50.8 × 1.65 47.5 63.9 112.7 43 83.5 220
65 – 63.5 × 1.65 60.2 77.4 127.7 43 100.0 220
80 3" 76.2 × 1.65 72.9 90.9 140.7 43 114.0 220
100 4" 101.6 × 1.65 97.4 118.9 166.7 43 141.0 220
1) L
tot
= fitting length
If pigs are used for cleaning, it is essential to take the inside diameters of
measuring tube and process connection (di) into account!
Coupling SC DIN 11851,
threaded adapter
1.4404 (F316L)
Sensor
DN
Fits to
piping
di G D L LK L
tot
1)
[mm] DN 11850 [mm] [mm] [mm] [mm] [mm] [mm]
A0005540
Order codes: 5*H**-2***********, DKH**-HG**
Surface roughness: R
a
0.8 m
40 42 × 1.5 38 Rd 65 × 1/6" 92.0 72 71.0 280
50 54 × 1.5 50 Rd 78 × 1/6" 105.0 74 83.5 284
65 70 × 2 66 Rd 95 × 1/6" 121.0 78 100.0 292
80 85 × 2 81 Rd 110 × ¹⁄" 140.7 114 114.0 362
100 104 × 2 100 Rd 130 × ¹⁄" 166.7 123 141.0 380
125 129 × 2 125 Rd 160 × ¹⁄" 198.7 93 171.0 380
150 154 × 2 150 Rd 160 × ¹⁄" 226.7 98 200.0 390
Order codes: 5*H**-2***********+CA/+CB, DKH**-HG**+CA/+CB
Surface roughness +CA: R
a
0.8 m
Surface roughness +CB: R
a
0.38 m
40 42 × 1.5 38 Rd 65 × 1/6" 99.7 63 71.0 260
50 54 × 1.5 50 Rd 78 × 1/6" 112.7 63 83.5 260
65 70 × 2 66 Rd 95 × 1/6" 127.7 68 100.0 270
80 85 × 2 81 Rd 110 × ¹⁄" 140.7 73 114.0 280
100 104 × 2 100 Rd 130 × ¹⁄" 166.7 78 141.0 290
1) L
tot
= fitting length
If pigs are used for cleaning, it is essential to take the inside diameters of
measuring tube and process connection (di) into account!