Proline Promag 50H, 53H
60 Endress+Hauser
Fitted electrodes Measuring electrodes and empty pipe detection electrodes
Standard with: 1.4435 (316L), Alloy C-22, Tantalum, Platinum
•DN 2 to 8 (¹ to 5/16"): without empty pipe detection electrode
Process connections With O-ring:
Weld sockets (DIN EN ISO 1127, ODT/SMS)
Flange (EN (DIN), ANSI, JIS)
PVDF flange (EN (DIN), ANSI, JIS)
External pipe thread
Internal pipe thread
Hose connection
PVC adhesive fittings
With gasket seals:
Weld sockets (EN 10357 (DIN 11850), ODT/SMS, ASME BPE, ISO 2037)
Clamps (ISO 2852, DIN 32676, L14 AM7)
Coupling (DIN 11851, DIN 11864-1, ISO 2853, SMS 1145)
Flange (DIN 11864-2)
Surface roughness Stainless steel electrodes, 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); platinum; tantalum:
0.3 to 0.5 m (11.8 to 19.7 in)
(All data relate to parts in contact with fluid)
Liner with PFA:
0,4 m (15.7 in)
(All data relate to parts in contact with fluid)
Stainless steel process connections:
With O-ring seal: 1.6 m (63 in)
With aseptic seal: 0.8 m (31.5 in)
Optional: 0.38 m (15 in)
(All data relate to parts in contact with fluid)
Operability
Local operation Display elements
Liquid crystal display: backlit, two lines (Promag 50) or four lines (Promag 53) with 16 characters
per line
Custom configurations for presenting different measured-value and status variables
•Totalizer
Promag 50: 2 totalizers
Promag 53: 3 totalizers
Operating elements
Unified operation concept for both types of transmitter:
Promag 50:
Local operation via three keys (, , )
Quick Setup menus for straightforward commissioning
Promag 53:
Local operation via three keys (, , )
Application-specific Quick Setup menus for straightforward commissioning
Language packages Language packages available for operation in different countries:
Promag 50, Promag 53:
Western Europe and America (WEA):
English, German, Spanish, Italian, French, Dutch, Portuguese
Eastern Europe and Scandinavia (EES):
English, Russian, Polish, Norwegian, Finnish, Swedish, Czech
South and east Asia (SEA):
English, Japanese, Indonesian

Table of Contents