Proline Promag 50H, 53H
Endress+Hauser 17
Length of connecting cable When mounting the remote version, please note the following to achieve correct measuring results:
Fix cable run or lay in armored conduit. Cable movements can falsify the measuring signal especially in the
case of low fluid conductivities.
Route the cable well clear of electrical machines and switching elements.
If necessary, ensure potential equalization between sensor and transmitter.
The permitted cable length L
max
is determined by the fluid conductivity. A minimum conductivity of
20 μS/cm is required for measuring demineralized water.
When the empty pipe detection function is switched on (EPD),
the maximum connecting cable length is 10 m (33 ft).
A0010734
Permitted length of connecting cable for remote version
Area marked in gray = permitted range; L
max
= length of connecting cable in [m] ([ft]); fluid conductivity in [μS/cm]
200
100
5
10 100 200
L
max
[m][m]
[µS/cm]
L
max
[ft]
200 6000