EasyManua.ls Logo

Endress+Hauser Proline Promag W 800 - Page 108

Endress+Hauser Proline Promag W 800
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data Proline Promag W 800
108 Endress+Hauser
0
0
20
40
100
60
140
[°F] [°C]
-20
-40
-40
T
A
T
F
1
-20
-10
0 10
20 30 40 50 60 70 80 90
0
100 200
[°C]
]F
50 150
A0038130
T
A
Ambient temperature
T
F
Medium temperature
1 Colored area: The ambient temperature range of –10 to –40 °C (+14 to –40 °F) and the medium temperature
range of –10 to –20 °C (+14 to –4 °F) only apply for stainless flanges.
For detailed information regarding the medium temperature in custody transfer, see
the Special Documentation →  120.
Conductivity ≥20 µS/cm for liquids in general.
Remote version
The necessary minimum conductivity also depends on the length of the connecting
cable →  29.
Pressure-temperature
ratings
For an overview of the pressure-temperature ratings for the process connections, see
the Technical Information →  120
Pressure tightness Liner: hard rubber
Nominal diameter Limit values for absolute pressure in [mbar] ([psi]) for medium
temperatures:
[mm] [in] +25 °C (+77 °F) +50 °C (+122 °F) +70 °C (+158 °F)
50 … 900 2 … 36 0 (0) 0 (0) 0 (0)
Liner: polyurethane
Nominal diameter Limit values for absolute pressure in [mbar] ([psi]) for medium temperatures:
[mm] [in] +25 °C (+77 °F) +50 °C (+122 °F)
25 … 900 1 … 36 0 (0) 0 (0)

Table of Contents

Other manuals for Endress+Hauser Proline Promag W 800

Related product manuals