Proline Promag W 800 Electrical connection
Endress+Hauser 47
7.2.4 Terminal assignment, Proline 800 - Advanced
Transmitter
Connection methods available
Possible options for order code
Outputs
Power
supply
Terminals Terminals "Electrical connection"
Option A: coupling M20x1
Option B: thread M20x1
Option C: thread G ½"
Option D: thread NPT ½"
Supply voltage
Order code for
"Power supply"
Terminal numbers Terminal voltage Frequency range
Option K, S 1 (L+/L), 2 (L-/N)
DC 24 V –20 to +25 %
AC 100 to 240 V –15 to +10 % 50/60 Hz, ±3 Hz
Order code for "Output"
and "Input"
Terminal numbers
20 21 22 23
Option I, K, M, N, P Pulse-/
switch output 2
Pulse-/
switch output 3
Pulse-/
switch output 1
Common
reference
potential (COM)
If a status input is also connected, the following terminals must be assigned, which are
located on the second terminal block of the IO board:
Order code for "Output" and "Input" Terminal numbers
24 25
Option I, M, P Positive terminal status input Negative terminal status input