3 Group SYSTEM UNITS Device Functions Proline Promass 80
10 Endress+Hauser
UNIT CORRECTED
VOLUME FLOW
Use this function to select the unit for displaying the corrected volume flow (corrected
volume/time).
The unit you select here is also valid for:
• Current outputs
• Frequency outputs
• Relay switch points (limit value for corrected volume flow, flow direction)
• Low flow cut off
Options:
Metric:
Nl/s
Nl/min
Nl/h
Nl/day
Nm
3
/s
Nm
3
/min
Nm
3
/h
Nm
3
/day
US:
Sm
3
/s;
Sm
3
/min;
Sm
3
/h;
Sm
3
/day
Scf/s;
Scf/min;
Scf/h;
Scf/day
Factory setting:
Nm
3
/h
UNIT CORR. VOLUME Use this function to select the unit for displaying the corrected volume.
The unit you select here is also valid for:
• Pulse value (e.g. Nm
3
/p)
Options:
Metric:
Nm
3
Nl
US:
Sm
3
Scf
Factory setting:
Nm
3
! Note!
The unit of the totalizers is independent of your choice here. The unit for each totalizer is
selected separately for the totalizer in question.
Function description SYSTEM UNITS