6 Group USER INTERFACE Device Functions Proline Promass 80
18 Endress+Hauser
100% VALUE
(Line 1)
! Note!
This function is not available unless one of the following was selected in the ASSIGN
LINE 1 function:
• MASS FLOW IN %
• VOLUME FLOW IN %
• CORRECTED VOLUME FLOW IN %
Use this function to define the flow value to be shown on the display as the 100% value
of the variable assigned to line 1.
User input:
5-digit floating-point number
Factory setting:
• 10 kg/s (if MASS FLOW IN % or MASS FLOW BARGRAPH IN % is selected)
• 10 l/s (if VOLUME FLOW IN % or VOLUME FLOW BARGRAPH IN % is selected)
100% VALUE
(Line 2)
! Note!
This function is not available unless one of the following was selected in the ASSIGN
LINE 2 function:
• MASS FLOW IN %
• VOLUME FLOW IN %
• MASS FLOW BARGRAPH IN %
• VOLUME FLOW BARGRAPH IN %
• CORRECTED VOLUME FLOW BARGRAPH IN %
Use this function to define the flow value to be shown on the display as the 100% value
of the variable assigned to line 2.
User input:
5-digit floating-point number
Factory setting:
• 10 kg/s (if MASS FLOW IN % or MASS FLOW BARGRAPH IN % is selected)
• 10 l/s (if VOLUME FLOW IN % or VOLUME FLOW BARGRAPH IN % is selected)
FORMAT Use this function to define the maximum number of places after the decimal point
displayed for the reading in the main line.
Options:
XXXXX. - XXXX.X - XXX.XX - XX.XXX -X.XXXX
Factory setting:
X.XXXX
! Note!
• Note that this setting only affects the reading as it appears on the display, it has no
influence on the accuracy of the system's calculations.
• The places after the decimal point as computed by the measuring device cannot always
be displayed, depending on this setting and the engineering unit. In these instances an
arrow appears on the display between the measured value and the engineering unit
(e.g. 1.2
→ kg/h), indicating that the measuring system is computing with more
decimal places than can be shown on the display.
Function description USER INTERFACE