PROline Promass 80 3 Installation
Endress+Hauser 17
Orientation Promass F, M, E, H, I
Make sure that the direction of the arrow on the nameplate of the sensor matches the
direction of flow (direction in which the fluid flows through the pipe).
Vertical:
Recommended orientation with upward direction of flow (View V). When fluid is not flow-
ing, entrained solids will sink down and gases will rise away from the measuring tube.
The measuring tubes can be completely drained and protected against solids build-up.
Horizontal (Promass F, M, E):
The measuring tubes of Promass F, M and E must be horizontal and beside each other.
When installation is correct the transmitter housing is above or below the pipe (View
H1/H2). Always avoid having the transmitter housing in the same horizontal plane as the
pipe.
Horizontal (Promass H, I):
Promass H and Promass I can be installed in any orientation in a horizontal pipe run.
✓✓ = Recommended orientation
✓ = Orientation recommended in certain situations
✗ = Impermissible orientation
Promass F, M, E, H, I
Standard, kompakt
Promass F, M, E, H, I
Standard, getrennt
Promass F
Hochtemperatur, kompakt
Promass F
Hochtemperatur, getrennt
Vertikale Einbaulage (Abb. V)
✓✓ ✓✓ ✓✓ ✓✓
Horizontale Einbaulage (Abb. H1)
Messumformerkopf oben
✓✓ ✓✓ ✗
(T
M
= >200 °C)
➀
✓
(T
M
= >200 °C)
➀
Horizontale Einbaulage (Abb. H2)
Messumformerkopf unten
✓✓
➁
✓✓
➁
✓✓
➁
✓✓
➁