EasyManua.ls Logo

Endress+Hauser Proline Promass E 100 - Page 14

Endress+Hauser Proline Promass E 100
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Proline Promass E 100
14 Endress+Hauser
Dynamic variables Read out the dynamic variables: HART command 3
The measured variables can be freely assigned to the dynamic variables.
Measured variables for PV (primary dynamic variable)
Mass flow
Volume flow
Corrected volume flow
Density
Reference density
Temperature
Measured variables for SV, TV, QV (secondary, tertiary and quaternary
dynamic variable)
Mass flow
Volume flow
Corrected volume flow
Density
Reference density
Temperature
Totalizer 1
Totalizer 2
Totalizer 3
The range of options increases if the measuring device has one or more
application packages.
Heartbeat Technology application package
Additional measured variables are available with the Heartbeat Technology
application package:
Oscillation amplitude 0
Device variables Read out the device variables: HART command 9
The device variables are permanently assigned.
A maximum of 8 device variables can be transmitted:
0 = mass flow
1 = volume flow
2 = corrected volume flow
3 = density
4 = reference density
5 = temperature
6 = totalizer 1
7 = totalizer 2
8 = totalizer 3
13 = target mass flow
14 = carrier mass flow
15 = concentration
PROFIBUS DP
Manufacturer ID 0x11
Ident number 0x1561
Profile version 3.02
Device description files (GSD,
DTM, DD)
Information and files under:
www.endress.com
On the product page for the device: Documents/Software → Device drivers
www.profibus.org
Заказывайте на сайте: www.tinnova.ru/endress_hauser/ || Эл. почта: info@tinnova.ru