Configurable Input Assembly Current device diagnostics
Mass flow
Volume flow
Corrected volume flow
Density
Reference density
Temperature
Totalizer 1
Totalizer 2
Totalizer 3
The range of options increases if the measuring device has one or
more application packages.
Fix Output
Output Assembly Activation of reset totalizers 1-3
Activation of pressure compensation
Activation of reference density compensation
Activation of temperature compensation
Reset totalizers 1-3
External pressure value
Pressure unit
External reference density
Reference density unit
External temperature
Temperature unit
Configuration
Configuration Assembly Only the most common configurations are listed below.
Software write protection
Mass flow unit
Mass unit
Volume flow unit
Volume unit
Corrected volume flow unit
Corrected volume unit
Density unit
Reference density unit
Temperature unit
Pressure unit
Length
Totalizer 1-3:
Assignment
Unit
Operating mode
Failsafe mode
Alarm delay
PROFINET
Protocol "Application layer protocol for decentral device periphery and distributed
automation", version 2.3
Conformity class B
Communication type 100 MBit/s
Device profile Application interface identifier 0xF600
Generic device
Manufacturer ID 0x11
Device type ID 0x844A
Device description files (GSD,
DTM)
Information and files under:
www.endress.com
On the product page for the device: Documents/Software → Device drivers
www.profibus.org
Baud rates Automatic 100 Mbit/s with full-duplex detection