Proline Promass E 100
24 Endress+Hauser
Depending on the housing version, the transmitters can be ordered with terminals or device plugs.
Order code
"Housing"
Connection methods available
Possible options for order code
"Electrical connection"
Outputs
Power
supply
Options
A, B
Terminals Terminals • Option A: coupling M20x1
• Option B: thread M20x1
•
Option C: thread G ½"
• Option D: thread NPT ½"
Options
A, B
Device plugs
→ 31
Terminals • Option L: plug M12x1 + thread NPT ½"
• Option N: plug M12x1 + coupling M20
• Option P: plug M12x1 + thread G ½"
• Option U: plug M12x1 + thread M20
Options
A, B, C
Device plugs
→ 31
Device plugs
→ 31
Option Q: 2 x plug M12x1
Order code for "Housing":
• Option A: compact, coated aluminum
• Option B: compact, hygienic, stainless
• Option C ultra-compact, hygienic, stainless
A0016888
2 Terminal assignment 4-20 mA HART with pulse/frequency/switch output
1
Power supply: DC 24 V
2 Output 1: 4-20 mA HART (active)
3 Output 2: pulse/frequency/switch output (passive)
Order code
"Output"
Terminal number
Power supply Output 1 Output 2
2 (L-) 1 (L+) 27 (–) 26 (+) 25 (–) 24 (+)
Option B DC 24 V 4-20 mA HART (active) Pulse/frequency/switch
output (passive)
Order code for "Output":
Option B: 4-20 mA HART with pulse/frequency/switch output