Proline Promass E 100
26 Endress+Hauser
Modbus RS485 connection version
For use in the non-hazardous area and Zone 2/Div. 2
Order code for "Output", option M
Depending on the housing version, the transmitters can be ordered with terminals or device plugs.
Order code
"Housing"
Connection methods available
Possible options for order code
"Electrical connection"
Output
Power
supply
Options
A, B
Terminals Terminals Option A: coupling M20x1
Option B: thread M20x1
Option C: thread G ½"
Option D: thread NPT ½"
Options
A, B
Device plugs
→  31
Terminals Option L: plug M12x1 + thread NPT ½"
Option N: plug M12x1 + coupling M20
Option P: plug M12x1 + thread G ½"
Option U: plug M12x1 + thread M20
Options
A, B, C
Device plugs
→  31
Device plugs
→  31
Option Q: 2 x plug M12x1
Order code for "Housing":
Option A: compact, coated aluminum
Option B: compact, hygienic, stainless
Option C ultra-compact, hygienic, stainless
L
L
26
27
A
B
1
2
+
_
1
2
A0019528
 4 Modbus RS485 terminal assignment, connection version for use in non-hazardous areas and Zone 2/Div.
2
1
Power supply: DC 24 V
2 Modbus RS485
Order code
"Output"
Terminal number
Power supply Output
1 (L+) 2 (L-) 26 (B) 27 (A)
Option M DC 24 V Modbus RS485
Order code for "Output":
Option M: Modbus RS485, for use in non-hazardous areas and Zone 2/Div. 2