EasyManua.ls Logo

Endress+Hauser Proline Promass E TB2 HART - Page 18

Endress+Hauser Proline Promass E TB2 HART
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Mounting Proline Promass E TB2 HART
18 Endress+Hauser
1
2
3
4
5
A0013500
å 4 Installation in a down pipe (e.g. for batching applications)
1 Supply tank
2 Sensor
3 Orifice plate, pipe restriction
4 Valve
5 Batching tank
DN
Æ Orifice plate, pipe restriction
[mm] [in] [mm] [in]
8 3/8 6 0.24
15 ½ 10 0.40
25 1 14 0.55
40 22 0.87
50 2 28 1.10
Orientation
The direction of the arrow on the sensor nameplate helps to match the sensor with the direction of
flow (direction of fluid flow through the pipe).
Orientation
Compact version
A
Vertical orientation
A0013493
B
Horizontal orientation, transmitter head
up
A0013491
Exception:
(® å 5, ä 19)
C
Horizontal orientation, transmitter head
down
A0013492
1)
Exception:
(® å 5, ä 19)

Table of Contents