Proline Promass E TB2 HART Commissioning
Endress+Hauser 55
10.4.2 Configuring the current outputs
The two wizards Current output 1-2 guide you systematically through all parameters that have to
be set in the configuration of the respective current output.
Navigation path
"Setup" menu ® Current output 1
"Setup" menu ® Current output 2
Sequence of the wizard
Part 1 (corresponding part 2: next page)
Assigncurrent
output
Off Massflow Volumeflow Density
Temperature
Massflowunit Volumeflowunit
Densityunit Temperatureunit
Currentspan
4mAvalue
20mA value
Failuremode
...Min.
Definedvalue
Failurecurrent
Endofwizard
*
4...20mA
NAMUR
4...20mAUS 4...20mA Fixedcurrent
A0013796-EN
å 12 "Current output 1-2" in the "Setup" menu (Part 1)
Off* = Option only for current output 2