Proline Promass E TB2 HART Commissioning
Endress+Hauser 57
Parameter overview with brief description
Parameters Description Selection/
User entry
Factory setting
Assign current output 1-2 Select the process variable for
current output.
Off (only for current
output 2)
Mass flow
Volume flow
Corrected volume flow
Density
Reference density
Temperature
Current output 1: mass
flow
Current output 2: off
Mass flow unit Select the unit for mass flow.
Result
The selected unit applies for:
Current outputs
Low flow cut off
Simulation process
variable
Unit picklist Country-dependent:
kg/h
lb/min
Volume flow unit Select the unit for volume
flow.
Result
The selected unit applies for:
Current outputs
Low flow cut off
Simulation process
variable
Unit picklist Country-dependent:
l/h
gal/min (us)
Density unit Select the unit for density.
Result
The selected unit applies for:
Current outputs
Low value partial filled
pipe detection
High value partial filled
pipe detection
Simulation process
variable
Density adjustment (in the
Expert menu)
Unit picklist Country-dependent
kg/l
lb/cf
Corrected volume flow unit Select the unit for corrected
volume flow.
Result
The selected unit applies for:
Current outputs
Low flow cut off
Simulation process
variable
Unit picklist Country-dependent:
Nl/h
Scf/min
Corrected volume flow
calculation
Select the reference density
for calculating the corrected
volume flow.
Fixed reference density
Calculated reference
density
Calculated reference density
Reference density unit Select the unit for reference
density.
Result
The selected unit applies for:
Current outputs
Low value partial filled
pipe detection
High value partial filled
pipe detection
Simulation process
variable
Fixed reference density
Density adjustment (in the
Expert menu)
Unit picklist
Country-dependent:
kg/Nl
lb/scf

Table of Contents