11.4 Adapting the measuring device to the process conditions
The following are available for this purpose:
•
Basic settings using the Setup menu (® ä 52)
•
Advanced settings using the Advanced setup menu (® ä 66)
11.5 Perform totalizer reset
In the Operation submenu, 2 parameters with various options for resetting the three totalizers are
available:
• Control totalizer 1-3
• Reset all totalizers
Navigation path
"Display/operat." menu ® Operation
"Operation" submenu
Operation
®
Control totalizer 1
Preset value 1
Control totalizer 2
Preset value 2
Control totalizer 3
Preset value 3
Reset all totalizers
Function scope of parameter "Set totalizer 1-3"
Options
Description
Reset + hold The totaling process is stopped and the totalizer is reset to 0.
Preset + hold The totaling process is stopped and the totalizer is set to the defined start value in the
Preset parameter.
Reset + totalize The totalizer is reset to 0 and the totaling process is restarted.
Preset + totalize The totalizer is set to the defined start value in the Preset parameter and the totaling process
is restarted.