Proline Promass F 100 Modbus RS485 Technical data
105
16.7 Installation
"Mounting requirements" →  20
16.8 Environment
Ambient temperature
range
→  23
Temperature tables
Observe the interdependencies between the permitted ambient and fluid
temperatures when operating the device in hazardous areas.
For detailed information on the temperature tables, see the separate document
entitled "Safety Instructions" (XA) for the device.
Storage temperature –40 to +80 °C (–40 to +176 °F), preferably at +20 °C (+68 °F) (standard version)
–50 to +80 °C (–58 to +176 °F) (Order code for "Test, certificate", option JM)
Climate class DIN EN 60068-2-38 (test Z/AD)
Degree of protection Transmitter and sensor
As standard: IP66/67, type 4X enclosure
With the order code for "Sensor options", option CM: IP69 can also be ordered
When housing is open: IP20, type 1 enclosure
Display module: IP20, type 1 enclosure
Safety Barrier Promass 100
IP20
Vibration resistance Vibration, sinusoidal according to IEC 60068-2-6
2 to 8.4 Hz, 3.5 mm peak
8.4 to 2 000 Hz, 1 g peak
Vibration broad-band random, according to IEC 60068-2-64
10 to 200 Hz, 0.003 g
2
/Hz
200 to 2 000 Hz, 0.001 g
2
/Hz
Total: 1.54 g rms
Shock resistance Shock, half-sine according to IEC 60068-2-27
6 ms 30 g
Impact resistance Rough handling shocks according to IEC 60068-2-31
Electromagnetic
compatibility (EMC)
As per IEC/EN 61326 and NAMUR Recommendation 21 (NE 21)
Complies with emission limits for industry as per EN 55011 (Class A)
Details are provided in the Declaration of Conformity.