Proline Promass F 100 Modbus RS485 Electrical connection
35
10 (0.4)
mm (in)
1 2
3
2
1
2
1
2
3
8 mm
3 mm
8 mm
A0017844
 12 Device versions with connection examples
1 Cable
2 Device plug for signal transmission
3 Device plug for supply voltage
Connect the cable in accordance with the terminal assignment or the device plug pin
assignment .
7.2.2 Connecting the Safety Barrier Promass 100
In the case of the device version with Modbus RS485 intrinsically safe, the transmitter
must be connected to the Safety Barrier Promass 100.
1. Strip the cable ends. In the case of stranded cables, also fit ferrules.
2. Connect the cable in accordance with the terminal assignment →  29.
3. Where applicable, enable the terminating resistor in the Safety Barrier Promass 100 .