Proline Promass F 300 EtherNet/IP Diagnostics and troubleshooting
197
Diagnostic information Remedy instructions Coding of diagnostic
information (hex)
No. Short text
144 Measuring error too high 1. Check or change sensor
2. Check process conditions
0x10001C7
Status signal F
Diagnostic behavior [from the
factory]
1)
Alarm
1) Diagnostic behavior can be changed.
12.8.2 Diagnostic of electronic
Diagnostic information Remedy instructions Coding of diagnostic
information (hex)
No. Short text
201 Device failure 1. Restart device
2. Contact service
0x100014B
Status signal F
Diagnostic behavior Alarm
Diagnostic information Remedy instructions Coding of diagnostic
information (hex)
No. Short text
242 Software incompatible 1. Check software
2. Flash or change main electronics
module
0x1000067
Status signal F
Diagnostic behavior Alarm
Diagnostic information Remedy instructions Coding of diagnostic
information (hex)
No. Short text
252 Modules incompatible 1. Check electronic modules
2. Change electronic modules
0x100006B
Status signal F
Diagnostic behavior Alarm
Diagnostic information Remedy instructions Coding of diagnostic
information (hex)
No. Short text
252 Modules incompatible 1. Check if correct electronic modul
is plugged
2. Replace electronic module
0x10002C0
Status signal F
Diagnostic behavior Alarm