Proline Promass I 100
Endress+Hauser 43
Order code for "Housing" T
a
[°C]
T6
[85 °C]
T5
[100 °C]
T4
[135 °C]
T3
[200 °C]
T2
[300 °C]
T1
[450 °C]
45 – 85 120 150
1)
150
2)
150
2)
50 – – 120 150
1)
150
2)
150
2)
1) The following applies for specified sensors with a maximum medium temperature T
m
= 200 °C: T
m
= 170 °C
2) The following applies for specified sensors with a maximum medium temperature T
m
= 200 °C: T
m
= 200 °C
US units
Order code for "Housing" T
a
[°F]
T6
[185 °F]
T5
[212 °F]
T4
[275 °F]
T3
[392 °F]
T2
[572 °F]
T1
[842 °F]
Option A "Compact coated alu"
Option B "Compact hygienic,
stainless"
95 122 185 248 302
1)
302
2)
302
2)
122 – 185 248 302
1)
302
2)
302
2)
140 – – 248 302
1)
302
2)
302
2)
Option C "Ultra compact hygienic,
stainless, M12 device plug"
95 122 185 248 302
1)
302
2)
302
2)
113 – 185 248 302
1)
302
2)
302
2)
122 – – 248 302
1)
302
2)
302
2)
1) The following applies for specified sensors with a maximum medium temperature T
m
= 392 °F: T
m
= 338 °F
2) The following applies for specified sensors with a maximum medium temperature T
m
= 392 °F: T
m
= 392 °F
Ex nA,
C
CSA
US
NI
SI units
Order code for "Housing" T
a
[°C]
T6
[85 °C]
T5
[100 °C]
T4
[135 °C]
T3
[200 °C]
T2
[300 °C]
T1
[450 °C]
Option A "Compact coated alu"
Option B "Compact hygienic,
stainless"
35 50 85 120 150
1)
150
2)
150
50 – 85 120 150 150 150
60 – – 120 150 150 150
Option C "Ultra compact hygienic,
stainless, M12 device plug"
50 – 85 120 150 150 150
60 – – 120 150 150 150
1) The following applies for specified sensors with a maximum medium temperature T
m
= 200 °C: T
m
= 170 °C
2) The following applies for specified sensors with a maximum medium temperature T
m
= 200 °C: T
m
= 200 °C
US units
Order code for "Housing" T
a
[°F]
T6
[185 °F]
T5
[212 °F]
T4
[275 °F]
T3
[392 °F]
T2
[572 °F]
T1
[842 °F]
Option A "Compact coated alu"
Option B "Compact hygienic,
stainless"
95 122 185 248 302
1)
302
2)
302
122 – 185 248 302 302 302
140 – – 248 302 302 302
Option C "Ultra compact hygienic,
stainless, M12 device plug"
122 – 185 248 302 302 302
140 – – 248 302 302 302
1) The following applies for specified sensors with a maximum medium temperature T
m
= 392 °F: T
m
= 338 °F
2) The following applies for specified sensors with a maximum medium temperature T
m
= 392 °F: T
m
= 392 °F