EasyManua.ls Logo

Endress+Hauser Proline Promass I 100 - Page 73

Endress+Hauser Proline Promass I 100
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Proline Promass I 100
Endress+Hauser 73
Order code for "Housing", option A "Compact, coated aluminum"
The various cable entries are suitable for hazardous and non-hazardous areas.
Cable entry/cable gland Material
Cable gland M20 × 1.5 Nickel-plated brass
Adapter for cable entry with internal thread G ½"
Adapter for cable entry with internal thread NPT ½"
Order code for "Housing", option B "Compact, hygienic, stainless"
The various cable entries are suitable for hazardous and non-hazardous areas.
Cable entry/cable gland Material
Cable gland M20 × 1.5 Stainless steel, 1.4404 (316L)
Adapter for cable entry with internal thread G ½"
Adapter for cable entry with internal thread NPT ½"
Device plug
Electrical connection Material
Plug M12x1 Socket: Stainless steel, 1.4404 (316L)
Contact housing: Polyamide
Contacts: Gold-plated brass
Sensor housing
Acid and alkali-resistant outer surface
Stainless steel 1.4301 (304)
Measuring tubes
Grade 9 titanium
Surface quality:
Not polished
Ra
max
= 0.8 µm (32 µin)
Ra
max
= 0.4 µm (16 µin)
Process connections
Flanges according to EN 1092-1 (DIN 2501) / according to ASME B16.5/ according to JIS:
Stainless steel 1.4301 (304)
Wetted parts: Grade 2 titanium
All other process connections:
Grade 2 titanium
List of all available process connections (→  74)
Seals
Welded process connections without internal seals
Safety Barrier Promass 100
Housing: Polyamide