Proline Promass I 100
74 Endress+Hauser
Process connections
Flanges:
EN 1092-1 (DIN 2501)
EN 1092-1 (DIN 2512N)
ASME B16.5
JIS B2220
Tri-Clamp (OD tubes)
Clamp (eccentric) :
Tri-Clamp
Threaded hygienic connection:
DIN 11851
SMS 1145
ISO 2853
DIN 11864-1 Form A
Flange:
DIN 11864-2 Form A
For information on the materials of the process connections (→  72)
Operability
Operating concept
Operator-oriented menu structure for user-specific tasks
Commissioning
Operation
Diagnostics
Expert level
Quick and safe commissioning
Individual menus for applications
Menu guidance with brief explanations of the individual parameter functions
Reliable operation
Operation in the following languages:
Via "FieldCare" operating tool:
English, German, French, Spanish, Italian, Chinese, Japanese
Via Web browser:
English, German, French, Spanish, Italian, Dutch, Portuguese, Polish, Russian, Turkish, Chinese,
Japanese, Bahasa (Indonesian), Vietnamese, Czech
Uniform operating philosophy applied to operating tools and Web browser
If replacing the electronic module, transfer the device configuration via the plug-in memory
(HistoROM DAT) which contains the process and measuring device data and the event logbook. No
need to reconfigure.
For devices with Modbus RS485, the data recovery function is implemented without the plug-in
memory (HistoROM DAT).
Efficient diagnostics increase measurement availability
Troubleshooting measures can be called up via the operating tools and Web browser
Diverse simulation options
Status indicated by several light emitting diodes (LEDs) on the electronic module in the housing
compartment
Local display
The local display is only available with the following device version:
Order code for "Display; Operation", option B: 4-line; via communication
Display element
4-line liquid crystal display with 16 characters per line.
White background lighting; switches to red in event of device errors.
Format for displaying measured variables and status variables can be individually configured.
Permitted ambient temperature for the display: –20 to +60 °C (–4 to +140 °F). The readability of
the display may be impaired at temperatures outside the temperature range.
Remote operation Via HART protocol
This communication interface is present in the following device version:
Order code for "Output", option B: 4-20 mA HART, pulse/frequency/switch output