Proline Prowirl 72 FOUNDATION Fieldbus 5 Operation
Endress + Hauser 31
5. 2 Display elements
5.2.1 Display
Local display
The local display enables you to read important parameters directly at the measuring point. The
display consists of two lines; this is where measured values and/or status variables (e.g. bar graph)
are displayed.
You can change the assignment of the display lines to suit your needs and preferences
(Page 107 ff.).
A0003802
Fig. 22: Liquid crystal display
The two-line liquid-crystal display shows measured values, fault messages and notice messages.
Top line: shows main measured values, e.g. calculated volume flow in [m³/h] or in [%].
Bottom line: shows additional measured variables and status variables, e.g. totalizer reading in [m³], bar graph, tag name
5.2.2 Display symbols
Display symbol Meaning
S System error
P Process error
$ Fault message
!Notice message
FF communication active
+48.25 m /h
3
+3702.6 m
3