Proline Prowirl F 200 PROFIBUS PA Diagnostics and troubleshooting
Endress+Hauser 145
12.5 Overview of diagnostic information
The amount of diagnostic information and the number of measured variables affected
increase if the measuring device has one or more application packages.
In the case of some items of diagnostic information, the diagnostic behavior can be
changed. Change the diagnostic information →  141
Operating conditions for displaying the following diagnostics information:
Diagnostics information 871: The process temperature is less than 2K from the
saturated steam line.
Diagnostics information 872: The measured steam quality has dropped below the
configured limit value for the steam quality (limit value: "Expert" menu → System
→ Diagnostic handling → Diagnostic limits → Steam quality limit).
Diagnostics information 873: The process temperature is ≤ 0 °C.
Diagnostics information 874: Wet steam detection/measurement is outside the
specified limits for the following process parameters: pressure, temperature,
velocity.
Diagnostics information 972: The degree of superheat has exceeded the configured
limit value (limit value: "Expert" menu → System → Diagnostic handling → Diagnostic
limits → Degrees of superheat limit).
12.5.1 Diagnostic of sensor
Diagnostic information Remedy instructions Influenced measured
variables
No. Short text
004 Sensor defective 1. Check plug connections
2. Change pre-amplifier
3. Change DSC sensor
Calculated saturated
steam pressure
Density
Energy flow
Flow velocity
Heat flow difference
Low flow cut off
Mass flow
Total mass flow
Switch output status
Pressure
Reynolds number
Specific volume
Corrected volume flow
Steam quality
Degrees of superheat
Volume flow
Measured variable status
Quality Bad
Quality substatus Maintenance alarm
Coding (hex) 0x24 to 0x27
Status signal F
Diagnostic behavior Alarm
Diagnostic information Remedy instructions Influenced measured
variables
No. Short text
022 Temperature sensor defective 1. Check plug connections
2. Change pre-amplifier
3. Change DSC sensor
Calculated saturated
steam pressure
Density
Energy flow
Heat flow difference
Mass flow
Total mass flow
Pressure
Reynolds number
Specific volume
Corrected volume flow
Steam quality
Degrees of superheat
Temperature
Measured variable status [from the factory]
1)
Quality Bad
Quality substatus Maintenance alarm
Coding (hex) 0x24 to 0x27
Status signal F
Diagnostic behavior Alarm
1) Diagnostic behavior can be changed. This causes the overall status of the measured variable to change.