Commissioning Proline Prowirl R 200 HART
100 Endress+Hauser
Parameter Prerequisite Description Selection / User
entry
Factory setting
Calorific value The following conditions are
met:
Selected medium:
In the Select gas type
parameter, the User-
specific gas option is
selected.
Or
In the Select liquid type
parameter, the User-
specific liquid option is
selected.
In the Enthalpy type
parameter, the Calorific
value option is selected.
In the Calorific value type
parameter, the Gross
calorific value volume
option or Gross calorific
value mass option is
selected.
Enter gross calorific value to
calculate the energy flow.
Positive floating-
point number
50 000 kJ/kg
Z-factor In the Select gas type
parameter, the User-specific
gas option is selected.
Enter real gas constant Z for
gas under operation
conditions.
0.1 to 2.0 1
Dynamic viscosity (Gases) The following conditions are
met:
Order code for "Sensor
version",
Option "Volume"
or
Option "Volume high
temperature"
The Gas option or the
Steam option is selected in
the Select medium
parameter.
or
The User-specific gas
option is selected in the
Select gas type parameter.
Enter fixed value for dynamic
viscosity for a gas/steam.
Dependency
The unit is taken from the
Dynamic viscosity unit
parameter.
Positive floating-
point number
0.015 cP
Dynamic viscosity (Liquids) The following conditions are
met:
Order code for "Sensor
version",
Option "Volume"
or
Option "Volume high
temperature"
The Liquid option is
selected in the Select
medium parameter
parameter.
or
The User-specific liquid
option is selected in the
Select liquid type
parameter.
Enter fixed value for dynamic
viscosity for a liquid.
Dependency
The unit is taken from the
Dynamic viscosity unit
parameter.
Positive floating-
point number
1 cP
Configuring the gas composition
In the Gas composition submenu the gas composition for the measuring application can
be set.