Proline Prowirl R 200 HART Technical data
Endress+Hauser 193
Sensor Maximum sensor measuring range MWP OPL
Lower (LRL) Upper (URL)
[bar (psi)] [bar (psi)] [bar (psi)] [bar (psi)]
2 bar (30 psi) 0 (0) +2 (+30) 6.7 (100.5) 10 (150)
4 bar (60 psi) 0 (0) +4 (+60) 10.7 (160.5) 16 (240)
10 bar (150 psi) 0 (0) +10 (+150) 25 (375) 40 (600)
40 bar (600 psi) 0 (0) +40 (+600) 100 (1 500) 160 (2 400)
Pressure loss For a precise calculation, use the Applicator→  171.
Vibrations
16.10 Mechanical construction
Design, dimensions
For the dimensions and installation lengths of the device, see the "Technical
Information" document, "Mechanical construction" section.
Weight Compact version
Single inner diameter line size reduction
Weight data:
Including the transmitter:
Order code for "Housing", option C "GT20, two-chamber, aluminum, coated, compact"
1.8 kg (4.0 lb):
Order code for "Housing", option B "GT18 two-chamber, 316L, compact"4.5 kg (9.9 lb):
Excluding packaging material
Weight in SI units
All values (weight) refer to devices with EN (DIN), PN 40 flanges. Weight information in
[kg].
DN
[mm]
Internal diameter
[mm]
Weight [kg]
Order code for "Housing", option C
"GT20 two-chamber, aluminum,
coated, compact"
1)
Order code for "Housing", option B
"GT18 two-chamber, 316L,
compact"
1)
25R 15 6.1 8.8
40R 25 10.1 12.8
50R 40 12.1 14.8
80R 50 16.1 18.8
100R 80 23.1 25.8
150R 100 42.1 44.8
200R 150 63.1 65.8
1) For high-temperature/low-temperature version: values + 0.2 kg
Weight in US units
All values (weight) refer to devices with ASME B16.5, Class 300/Sch. 40 flanges. Weight
information in [lbs].