EasyManua.ls Logo

Endress+Hauser Proline Prowirl R 200 - Page 199

Endress+Hauser Proline Prowirl R 200
212 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Proline Prowirl R 200 HART Technical data
Endress+Hauser 199
Pressure ratings PN 10/16/25/40, Class 150/300, as well as JIS 10K/20K:
Parts in contact with medium (marked as "wet" on the DSC sensor flange):
Stainless steel 1.4404 and 316 and 316L
Compliant with:
NACE MR0175/ISO 15156-2015
NACE MR0103/ISO 17945-2015
Parts not in contact with medium:
Stainless steel 1.4301 (304)
Order code for "Sensor version; DSC sensor; measuring tube", option AB, BB, CB
Pressure ratings PN 10/16/25/40, Class 150/300, as well as JIS 10K/20K:
Parts in contact with medium (marked as "wet" on the DSC sensor flange):
Alloy C22, UNS N06022 similar to Alloy C22/2.4602
Compliant with:
NACE MR0175/ISO 15156-2015
NACE MR0103/ISO 17945-2015
Parts not in contact with medium:
Alloy C22, UNS N06022 similar to Alloy C22/2.4602
Pressure measuring cell
The "mass" sensor version (integrated pressure/temperature measurement) is
available only for measuring devices in the HART communication mode.
Wetted parts:
Process connection
Stainless steel, 1.4404/316L
Membrane
Stainless steel, 1.4435/316L
Non-wetted parts:
Housing
Stainless steel ,1.4404
Order code for "Sensor version; DSC sensor; measuring tube", option DA, DB
Siphon
5)
Stainless steel ,1.4571
Adjusting nut
Stainless steel ,1.4571
Pressure gauge valve
Stainless steel ,1.4571
Welded connection on meter body
Stainless steel, multiple certifications 1.4404/316/316L
Seals
Copper
Process connections
DN 25R to 200R (1R to 8R")/DN 40S to 250S (1½S to 10S"), pressure ratings PN
10/16/25/40, Class 150/300, as well as JIS 10K/20K:
"R-type" with single inner diameter line size reduction: 25R to 200R (1R to 8R")
Compliant with:
NACE MR0175-2003
NACE MR0103-2003
"S-type" with double inner diameter line size reduction: DN 40S to 250S (1½S to 10S")
Compliant with:
NACE MR0175-2003
NACE MR0103-2003
5) Only with order code for "Sensor version; DSC sensor; measuring tube", option DA available.