Technical data Proline Prowirl R 200 HART
200 Endress+Hauser
The following materials are available depending on the pressure rating:
Stainless steel, multiple certifications, 1.4404/F316/F316L)
List of all available process connections
Seals
Graphite (standard)
Sigraflex foil
TM
(BAM-tested for oxygen applications, "high-grade in the context of TA-
Luft Clean Air Guidelines")
FPM (Viton
TM
)
Kalrez 6375
TM
Gylon 3504
TM
(BAM-tested for oxygen applications, "high-grade in the context of TA-
Luft clean air guidelines")
Order code for "Sensor version; DSC sensor; measuring tube", option DA, DB
Copper
Housing support
Stainless steel, 1.4408 (CF3M)
Screws for DSC sensor
Order code for "Sensor version", option AA, BA, CA, DA, DB
Stainless steel, A2-80 according to ISO 3506-1 (304)
Order code for "Additional approval", option LL "AD 2000 (including option JA+JB+JK) >
DN25 including option LK"
Stainless steel, A4-80 according to ISO 3506-1 (316)
Order code for "Sensor version", option AB, AC, BB, CB, CC
Stainless steel, 1.4980 according to EN 10269 (Gr. 660 B)
Accessories
Protective cover
Stainless steel, 1.4404 (316L)
Flow conditioner
Stainless steel, multiple certifications, 1.4404 (316, 316L)
Compliant with:
NACE MR0175-2003
NACE MR0103-2003
Process connections DN 25R to 200R (1R to 8R")/DN 40S to 250S (1½S to 10S"), pressure ratings PN
10/16/25/40, Class 150/300, as well as JIS 10K/20K:
"R-type" with single inner diameter line size reduction: 25R to 200R (1R to 8R")
Compliant with:
NACE MR0175-2003
NACE MR0103-2003
"S-type" with double inner diameter line size reduction: DN 40S to 250S (1½S to 10S")
Compliant with:
NACE MR0175-2003
NACE MR0103-2003
The following materials are available depending on the pressure rating:
Stainless steel, multiple certifications, 1.4404/F316/F316L)
List of all available process connections