Proline Prowirl R 200 HART Installation
Endress+Hauser 23
Pressure measuring cell
Steam pressure measurement Option DA
E • With the
transmitter
installed at the
bottom or at the
side
• Protection
against rising
heat
• Reduction in
temperature to
almost ambient
temperature due
to siphon
1)
A0034057
F
A0034058
Gas pressure measurement Option DB
G • Pressure
measuring cell
with shut off
device above
tapping point
• Discharge of any
condensate into
the process
A0034092
Liquid pressure measurement Option DB
H Device with shut
off device at the
same level as
tapping point
A0034091
1) Note max. permitted ambient temperature of transmitter→ 26.
Minimum spacing and cable length
Order code for "Sensor version", option "mass" DA, DB
The "mass" sensor version (integrated pressure/temperature measurement) is
available only for measuring devices in the HART communication mode.
A0019211
A Minimum spacing in all directions
L Required cable length