Operation options Proline Prowirl R 200 HART
52 Endress+Hauser
8.2.2 Operating philosophy
The individual parts of the operating menu are assigned to certain user roles (operator,
maintenance etc.). Each user role contains typical tasks within the device lifecycle.
Menu/parameter User role and tasks Content/meaning
Language task-oriented Role "Operator", "Maintenance"
Tasks during operation:
Configuring the operational display
Reading measured values
Defining the operating language
Resetting and controlling totalizers
Operation Configuring the operational display (e.g. display format, display contrast)
Resetting and controlling totalizers
Setup "Maintenance" role
Commissioning:
Configuration of the measurement
Configuration of the inputs and
outputs
Wizards for fast commissioning:
Set the system units
Define the medium
Configure the current input
Configure the outputs
Configuring the operational display
Define the output conditioning
Set the low flow cut off
Advanced setup
For more customized configuration of the measurement (adaptation to
special measuring conditions)
Configuration of totalizers
Configure the WLAN settings
Administration (define access code, reset measuring device)
Diagnostics "Maintenance" role
Fault elimination:
Diagnostics and elimination of
process and device errors
Measured value simulation
Contains all parameters for error detection and analyzing process and
device errors:
Diagnostic list
Contains up to 5 currently pending diagnostic messages.
Event logbook
Contains event messages that have occurred.
Device information
Contains information for identifying the device.
Measured values
Contains all current measured values.
Data logging submenu with "Extended HistoROM" order option
Storage and visualization of measured values
Heartbeat
The functionality of the device is checked on demand and the verification
results are documented.
Simulation
Is used to simulate measured values or output values.
Expert function-oriented Tasks that require detailed
knowledge of the function of the
device:
Commissioning measurements
under difficult conditions
Optimal adaptation of the
measurement to difficult
conditions
Detailed configuration of the
communication interface
Error diagnostics in difficult cases
Contains all the parameters of the device and makes it possible to access
these parameters directly using an access code. The structure of this menu is
based on the function blocks of the device:
System
Contains all higher-order device parameters which do not concern the
measurement or the communication interface.
Sensor
Configuration of the measurement.
Input
Configuration of the input.
Output
Configuration of the outputs.
Communication
Configuration of the digital communication interface.
Application
Configure the functions that go beyond the actual measurement (e.g.
totalizer).
Diagnostics
Error detection and analysis of process and device errors and for device
simulation and Heartbeat Technology.