Commissioning Proline Prowirl R 200 HART
78 Endress+Hauser
Parameter Prerequisite Description Selection Factory setting
Pressure unit With order code for "Sensor
version":
option "Mass (integrated
temperature measurement)"
or
option "Mass (integrated
pressure/temperature
measurement)"
Select process pressure unit.
Result
The unit is taken from:
Calculated saturated steam
pressure
Atmospheric pressure
Maximum value
Fixed process pressure
Pressure
Reference pressure
Unit choose list Country-specific:
bar
psi
Temperature unit Select temperature unit.
Result
The selected unit applies for:
Temperature
Maximum value
Minimum value
Average value
Maximum value
Minimum value
Maximum value
Minimum value
2nd temperature delta heat
Fixed temperature
Reference combustion
temperature
Reference temperature
Saturation temperature
Unit choose list Country-specific:
°C
°F
Energy flow unit With order code for "Sensor
version":
Option "Mass (integrated
temperature measurement)"
or
Option "Mass (integrated
pressure/temperature
measurement)"
Select energy flow unit.
Result
The selected unit applies for:
Heat flow difference
parameter
Energy flow parameter
Unit choose list Country-specific:
kW
Btu/h
Energy unit With order code for "Sensor
version":
Option "Mass (integrated
temperature measurement)"
or
Option "Mass (integrated
pressure/temperature
measurement)"
Select energy unit. Unit choose list Country-specific:
kWh
Btu
Calorific value unit The following conditions are
met:
Order code for "Sensor
version",
Option "Mass (integrated
temperature
measurement)"
or
Option "Mass (integrated
pressure/temperature
measurement)"
The Gross calorific value
volume option or the Net
calorific value volume
option is selected in the
Calorific value type
parameter.
Select calorific value unit.
Result
The selected unit applies for:
Reference gross calorific value
Unit choose list Country-specific:
kJ/Nm³
Btu/Sft³

Table of Contents