6 Endress+Hauser
4 Safety instructions
Check whether the spare part matches the labeling on the measuring device as described on
the cover page.
The spare part sets and Installation Instructions are used to replace a faulty unit with a
functioning unit of the same type.
Only use original parts from Endress+Hauser.
Comply with national regulations governing mounting, electrical installation,
commissioning, maintenance and repair procedures.
The following requirements must be met with regard to specialized technical staff for the
mounting, electrical installation, commissioning, maintenance and repair of the measuring
devices:
Specialized technical staff must be trained in instrument safety.
They must be familiar with the individual operating conditions of the devices.
In the case of Ex-certified measuring devices, they must also be trained in explosion
protection.
The measuring device is energized! Risk of fatal injury from electric shock. Open the
measuring device only when the device is de-energized.
For measuring devices intended for use in hazardous locations, please observe the
guidelines in the Ex documentation (XA).
In the case of measuring devices in safety-related applications in accordance with
IEC 61508 or IEC 61511: Commission in accordance with Operating Instructions after
repair. Document the repair procedure.
Before removing the device: set the process to a safe state and purge the pipe of dangerous
process substances.
Hot surfaces! Risk of injury! Before commencing work: allow the system and measuring
device to cool down to a touchable temperature.
In the case of devices in custody transfer, the custody transfer status no longer applies once
the seal has been removed.
The Operating Instructions for the device must be followed.
Risk of damaging the electronic components! Ensure you have a working environment
protected from electrostatic discharge.
After removing the electronics compartment cover: risk of electrical shock due to missing
touch protection!
Turn the measuring device off before removing internal covers.
Modifications to the measuring device are not permitted.
Only open the housing for a brief period. Avoid the penetration of foreign bodies, moisture
or contaminants.
Replace defective seals only with original seals from Endress+Hauser.
If threads are damaged or defective, the measuring device must be repaired.
Threads (e.g. of the electronics compartment cover and connection compartment cover)
must be lubricated if an abrasion-proof dry lubricant is not available. Use acid-free, non-
hardening lubricant.