6.6 Data storage device (DAT, F-Chip)
S-DAT (Sensor-DAT)
The S-DAT is an exchangeable data storage chip in which all sensor relevant param-
eters are stored, i.e., diameter, serial number, calibration factor, zero point.
T-DAT (Transmitter-DAT)
The T-DAT is an exchangeable data storage chip in which all transmitter parameters
and settings are stored.
The user has to transfer specific parameterisation values from EEPROM to T-DAT and
vice versa. See the Description of Device Functions manual for details (T- D AT
ADMINISTRATION function, No. 1009).
F-Chip (Function-Chip)
The F-Chip is a microprocessor chip that contains additional software packages that
extend the functionality and application possibilities of the transmitter. In the case of a
later upgrade, the F-Chip can be ordered as an accessory (see Page 111) and can
simply be plugged on to the I/O board (see Page 122). After start up, the software is
immediately made available to the transmitter.
Caution:
To ensure an unambiguous assignment, the F-Chip is coded with the transmitter serial
number once it is plugged in. Thus, it can not be reused with other transmitters.