Promag 53 PROFIBUS-DP/-PA 10 Technical data
Endress+Hauser 171
Coupling SMS 1145
1.4404 / 316L
5*H**-5***********
DN
[mm]
di
[mm]
G
[mm]
D
[mm]
L
[mm]
LK
[mm]
40 35.5 Rd 60 x 1/6" 92 63 71.0
50 48.5 Rd 70 x 1/6" 105 65 83.5
65 60.5 Rd 85 x 1/6" 121 70 100.0
80 72.0 Rd 98 x 1/6" 147 75 121.0
100 97.6 Rd 132 x 1/6" 168 70 141.5
Fitting length = (2 x L) + 140 mm (DN 40...65) / + 200 mm (DN 80...100)
If pigs are used for cleaning, it is essential to take the inside diameters of measuring tube (Page 158)
and process connection (di) into account.
F06-xxHxxxxx-06-09-07-xx-000
Coupling ISO 2853
1.4404 / 316L
5*H**-6***********
DN
[mm]
di
[mm]
G
[mm]
D
[mm]
L
[mm]
LK
[mm]
40 35.6 50.6 92 61.5 71.0
50 48.6 64.1 105 61.5 83.5
65 60.3 77.6 121 61.5 100.0
80 72.9 91.1 147 61.5 121.0
100 97.6 118.1 168 61.5 141.5
Fitting length = (2 x L) + 140 mm (DN 40...65) / + 200 mm (DN 80...100)
If pigs are used for cleaning, it is essential to take the inside diameters of measuring tube (Page 158)
and process connection (di) into account.
F06-xxHxxxxx-06-09-07-xx-003