6 Commissioning Promag 53 PROFIBUS-DP/-PA
88 Endress+Hauser
4. Parametering the “Totalizer Block”:
Promag 53 comprises three Totalizer function blocks. These are selected using the
profile blocks “Totalizer Block” in the connection clearance list.
– Enter the required name for the Totalizer function block.
Factory setting: TOTALIZER BLOCK
– Select the process variable (e.g. Volume flow) with the parameter CHANNEL
(V8H5).
– Enter the required units for the totalizer (UNIT TOTALIZER, V1H0).
– Configure the totalizer, e.g. for totalizing (SET TOT, V1H1).
– Configure the totalizer mode, e.g. balancing (TOTALIZER MODE, V1H3).
5. Configuration of the cyclic data traffic:
– All the relevant data is described in Chapter “System Integration” (see Page 90).
– We recommend that the “Coupling Documentation” be used for step-by-step
configuration. This can be obtained from Endress+Hauser Process Solutions for
various automation control systems and programmable logic controls.
– The files required for commissioning and network configuration can be obtained
as described on Page 90.