Prosonic M
44 Endress+Hauser
Remote display FHX40
L00-FMxxxxxx-00-00-06-de-003
Technical data (cable and housing) and product structure:
Order information FHX40
For connection of the remote display FHX40 use the cable which fits the communication version of the
respective instrument.
Max. cable length 20 m (65 ft)
Temperature range -40 °C to +60 °C (-40 °F to +140 °F)
Degree of protection IP65/67 (housing); IP68 (cable) acc. to IEC 60529
Dimensions [mm] / [inch] 122x150x80 (HxWxD) / 4.8x5.9x3.2
010 Approval:
A Non-hazardous area
2 ATEX II 2G Ex ia IIC T6
3 ATEX II 2D Ex ia IIIC T80°C
G IECEx Zone1 Ex ia IIC T6/T5
S FM IS Cl. I Div.1 Gr. A-D, zone 0
U CSA IS Cl. I Div.1 Gr. A-D, zone 0
N CSA General Purpose
K TIIS Ex ia IIC T6
C NEPSI Ex ia IIC T6/T5
Y Special version, TSP-Nr. to be spec.
020 Cable:
1 20m / 65ft: for HART
5 20m / 65ft: for PROFIBUS PA/FOUNDATION Fieldbus
9 Special version, TSP-Nr. to be spec.
030 Additional option:
A Basic version
B Mounting bracket, pipe 1"/ 2"
Y Special version, TSP-Nr. to be spec.
995 Marking:
1Tagging (TAG)
FHX40 - Complete product designation
E
N
D
R
E
S
S
+
H
A
U
S
E
R
I
P
6
5
O
r
de
r C
od
e
:
Se
r
.-N
o
.:
M
e
s
s
b
er
ei
ch
M
ea
su
r
in
g
r
a
n
ge
Messbereich
Measuring range
U
1
6
...
36
V
D
C
4
...2
0 m
A
m
a
x
.
20
m
Made in Germany Maulburg
T>
7
0
°C
:
A
t
>
8
5
°
C
82 (3.23)
6,3
(0.25)
106 (4.71)
122 (4.8)
120 (4.72)
mm (in)
max. 80 (3.15)
min. 30 (1.18)
96 (3.78)
88
160 (6.3)
8,5
(0.33)
118 (4.65)
180 (7.09)
Micropilot M
Levelflex M
Prosonic M
122
(4.8)
80
(3.51)
150 (5.91)
Separate housing
FHX40 (IP 65)
Cable
Wall-mounting
(without mounting bracket)
Pipe-mounting
(mounting bracket and plate
supplied optionally,
s. product structure)
pipe