Mounting Prosonic M FOUNDATION Fieldbus
10 Endress+Hauser
L00-FMU4KAxx-17-00-00-yy-004
BD: blocking distance; SD: safety distance; E: empty calibration; F: full calibration (span); D: nozzle diameter; L: nozzle
length
"
Caution!
If the blocking distance is undershot, it may cause device malfunction.
F
E
BD
SD
L
D
FMU40/41
L
D
FMU43
L
D
FMU42/44
Maximum nozzle length[mm (inch)]
Nozzle diameter FMU40 FMU41 FMU42 FMU43 FMU44
DN50/2" 80 (3.15)
DN80/3" 240 (9.45) 240 (9.45) 250 (9.84)
DN100/4" 300 (11.8) 300 (11.8) 300 (11.8) 300 (11.8)
DN150/6" 400 (15.7) 400 (15.7) 400 (15.7) 300 (11.8) 400 (15.7)
DN200/8" 400 (15.7) 400 (15.7) 400 (15.7) 300 (11.8) 400 (15.7)
DN250/10" 400 (15.7) 400 (15.7) 400 (15.7) 300 (11.8) 400 (15.7)
DN300/12" 400 (15.7) 400 (15.7) 400 (15.7) 300 (11.8) 400 (15.7)
Emitting angle α 11° 11° 9° 6° 11°
Blocking distance [m (ft)] 0,25 (0.8) 0,35 (1.1) 0,4 (1.3) 0,6 (2.0) 0,5 (1.6)
Max. range [m(ft)]
in liquids
5 (16) 8 (26) 10 (33) 15 (49) 20 (66)
Max. range [m (ft)]
in solids
2 (6.6) 3,5 (11) 5(16) 7 (23) 10 (33)