13.1.11 Triangular weirs
L00-FMU90xxx-05-00-00-xx-011
!
Note!
After selecting the type of weir, Q
max
can be adjusted to the flow conditions. Q
max
defines the flow
at which the output current is 20 mA.
Type of weir α H
max
[mm] Q
max
[m
3
/h]
V-Weir 22,5 22,5° 600 276,0
V-Weir 30 30° 600 371,2
V-Weir 45 45° 600 574,1
V-Weir 60 60° 600 799,8
V-Weir 90 90° 600 1385
kk
45°
BD
3H
max
2H
max
H
max
2H
max
k3mm
α