The "flow" menu
45
The "flow N state" parameter set appears, in which the currently measured level, distance and
flow are displayed. Compare the displayed distance to the real distance in order to decide if a further
mapping is necessary.
If yes: Press the left-arrow key () in order to return to the "flow N mapping" parameter set.
If no: Press the right key () in order to return to the "flow N" submenu.
"status"
see below ("flow N status")
"flow N state" (N = 1 or 2)"
"level"
Displays the currently measured level.
"sensor"
Dispalys the currently measured distance between the sensor membrane and the liquid surface.
"flow N" (N = 1 or 2)
Displays the currently measured flow.
"status"
Use this parameter to define the status of the interference echo suppression.
enable map
Choose this option in order activate the interference echo suppression. The mapping is then used
for signal evaluation.
disable map
Choose this option in order to deactivate the interference echo suppression. The mapping is then
no longer used for signal evaluation but it can be reactivated if required.
delete map
Choose this option in order to delete the mapping. It can not be reactivated again and the
instrument uses the preprogrammed default mapping.
LVL1 state L100C
level:
sensor:
flow N:
status: