The "flow" menu
60
3.2.4 The "simulation" submenu
"backwater simulation"
"simulation"
Use this parameter to select the simulation mode:
sim. off
This is the normal mode used for measurement. No simulation is performed in this mode.
sim. level
After selection of this mode, the "sim. level value" parameter appears, where you can specify a
level value. The backwater and dirt detection generate a ratio h
2
/h
1
according to this level.
!
Note!
An error message is generated as long as the "sim. level" mode is active.
"sim. level value"
This parameter is available for a level simulation. It is used ot specify the desired level value.
backw simulation F1600
simulation:
(sim. level value:)
The parameters of this set are used to simulate a downstream water
level in order to check the parametrisation of the backwater and dirt
detection.