Endress+Hauser Prothermo NMT81 - Mounting NMT81 on a Cone Roof Tank

Endress+Hauser Prothermo NMT81
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Prothermo NMT81 Installation
Endress+Hauser 27
R
a
A0042789
 16 Installation and winding of a temperature probe
a 600 mm (23.62 in) or more
R 300 mm (11.81 in) or more
L
CAUTION
If bending the temperature probe with R smaller than 300 mm (11.81 in), it may damage
the probe and elements.
Bend the probe 300 mm (11.81 in) or more.
5.9.3 Installation height adjustment
A unique feature of NMT81 is the optional ability to adjust height by approx.
±180 mm (7.09 in) from the original position.
The height adjustment feature is not available for the welded flange type and the converter-
only version.
5.10 Installation procedure
The length of the NMT81 probe is predetermined by the customer. Check the following items
before installing.
Tag number on the device
Length of the temperature probe
Number of elements