Accessories Waterpilot FMX21
120 Endress+Hauser
NOTICE
The marking is used exclusively for installation purposes.
The mark must be thoroughly removed without trace in the case of devices with
drinking water approval. The extension cable must not be damaged in the process.
Not for use of the FMX21 in hazardous areas.
B
A
A0018792
A Cable marking
B Cable marking tolerance
15.10 Testing adapter
15.10.1 For FMX21 with external diameter of 22 mm (0.87 in) or
29 mm (1.14 in)
Endress+Hauser offers a testing adapter to ease function-testing of the level probes.
Observe the maximum pressure for compressed air hose and maximum overload for level
probe →  122
Maximum pressure for the quick coupling piece provided: 10 bar (145 psi)
Adapter material: 304 (1.4301)
Material of quick coupling piece: anodized aluminum
Weight: 39 g (1.376 oz)
Order number 52011868
Ordering information: Product Configurator order code for "Accessories enclosed", option
"PV"