Waterpilot FMX21 Description of device parameters
Endress+Hauser 83
14.3 Expert → System → Management
Enter reset code
Write permission Operators/Service engineers/Expert
Description Reset parameters completely or partially to the factory values or order configuration by
entering a reset code, see "Resetting to factory settings (reset)" section.
Factory setting 0
14.4 Expert → Measurement → Measuring mode
Measuring mode
L
WARNING
Changing the measuring mode affects the span (URV)
This situation can result in product overflow.
‣
If the measuring mode is changed, the setting for the span (URV) must be checked in
the "Setup" operating menu and readjusted if necessary.
Write permission Operators/Service engineers/Expert
Description Select the measuring mode. The operating menu is structured differently depending on the
measuring mode selected.
Options • Meas.
• Level
Factory setting Pressure or according to order specifications