EGM-PWML ENERGY METER WITH MEMORY
All brands and logos are registered trademarks of their respective owners
Features
USB Energy Meter, creates exact insight in your energy consumption
(voltage/current/power)
No permanent computer connection required
Stores 34 hours of energy consumption data in the internal memory
Power Meter software helps calculating the actual energy costs of your
equipment
Software provides basic power consumption readings (home use) and
advanced readings (business/scientific use)
Specifications
Input: 220-240 V AC 50-60 Hz
Load max: 10 A
Power consumption max: 1.2W
USB 1.1 or 2.0 compatible interface
Computer measurements: voltage and current measuring (RMS values), true
power measuring, real energy consumed during a time period (kWh)
Measurements range: up to 250 V AC, 10 A (RMS), 2500 W, 22 MW a
year
Measurements accuracy: ± 2% (within 50 W - 2500 W power range)
FLASH memory: 128 KB
Working conditions: (+ 10 to 40) C, below 90 % humidity
Dimensions: 130 mm x 92 mm x 72 mm
Net weight: 0.3 kg