3.3
Battery
Cells
3.3.1
Power
Reserve:
The
power
storage
capacity
marked
by
the
power
supply
are
rated
values.
The
rated
power
storage
of
the
power
supply
is
shown
in
the
parameter
label
in
the
power
supply
manual,
which
is
usually
marked
directly
*Wh,
and
also
marked
with
the
rated
voltage
(V)
and
rated
ca-
pacity
(mAh),
and
the
power
storage
(Wh)
=
rated
voltage
*
rated
capa-
city
(mAh)
/1000.
3.3.2
The
Actual
Power
Discharged
From
the
Power
Supply:
The
actual
power
discharged
by
the
power
supply
is
related
to
the
fol-
lowing
parameters:
1)
Ambient
Temperature
Ambient
temperature
has
a
large
impact
on
the
amount
of
power
rele-
ased
from
the
battery.
For
example,
the
range
of
electric
vehicles
will
be
shortened
when
used
in
cold
areas.
Generally
speaking,
based
on
the
rated
25
°C
(77°F),
for
every
10
°C(50°F)
lower
than
0°C(32°F),
the
power
released
will
be
reduced
by
10-15%.
For
every
10
°C(50°F)
below
0°C(32°F),
the
amount
of
power
discharged
will
be
reduced
by
30%.
2)
Efficiency
During
the
discharge
process,
the
battery
voltage
needs
to
be
transfor-
med,
which
inevitably
brings
energy
loss,
especially
in
the
inverter
(AC
output)
part,
which
is
affected
by
the
ambient
temperature
and
the
power
level
of
the
equipment
being
run,
with
losses
ranging
from
5-15%.
Therefore,
the
measured
power
discharged
from
the
output
side
under
full
load
is
only
85%-95%
of
the
rated
capacity.