Enernova ETA - Troubleshooting; Charging and Shutdown Problems

Enernova ETA
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.
Troubleshooting
5.1
Charging
Failure
5.1.1
The
input
and
output
of
the
adapter
are
not
plugged
into
place:
Plug
the
input
and
output
of
the
adapter
into
place.
5.1.2
Mismatched
adapter:
Use
the
adapter
provided
with
the
product.
5.1.3
The
ambient
temperature
is
too
high:
Lithium
batteries
are
extremely
dangerous
to
use
beyond
the
specified
temperature,
so
if
the
ambient temperature
is
very
low
or
very
high,
the
internal
temperature
protection
of
the
product
will
stop
charging
and
discharging.
In
this
case,
please
wait
for
the
product
temperature
to
re-
cover
before
use.
5.1.4
Adapter
failure:
Judge
by
observing
the
indicator
light
on
the
adapter,
if
the
indicator
light
is
not
on,
prove
the
adapter
failure,
replace
the
adapter.
5.1.5
Circuit
failure:
Judgment
condition
is
that
the
adapter
is
normal
and
the
above
faults
can
still
not
be
charged
normally,
then
professional
maintenance
is
required.
5.2
Automatic
Shutdown
When
Loading
5.2.1
The
power
of
the
rear
stage
load
exceeds
the
specified
value
(the
alarmicon
&
of
the
display
will
light
up after
the
power
supply
cuts
off
the
output).
Please
note
that
some
loads
have
a
high
starting
cur-
rent
although
the
nominal
power
is
small,
which
will
also
cause
the
product
to
enter
the
overload
protection
state.
5.2.2
There
is
a
short-circuit
fault
in
the
rear
load
(the
alarm
icon
/1
of
the
display
will
light
up
when
the
power
is
turned
off
quickly):
the
con-
firmation
of
this
fault
needs
to
be
measured
by
professionals
using
special
tools
(such
as
measuring
the
resistance
of
the
rear
device
with
a
multimeter).