The DSL-100 is a digital, heat-only thermostat designed for accurate control and display of room temperature. It offers a user-friendly interface with clearly marked buttons and an informative display, making it easy to understand and operate. This electronic control replaces conventional mechanical anticipators and provides various functions for optimal heating management.
The thermostat's primary function is to maintain a desired room temperature by controlling heating equipment. It operates solely in the heat mode. The display shows the current room temperature, the operating mode, and whether heating is currently active.
Temperature Setting: Users can select the desired temperature for their heating equipment by pressing the up or down arrow buttons.
Celsius/Fahrenheit Display: The thermostat allows users to switch between Celsius (°C) and Fahrenheit (°F) temperature displays by simultaneously pressing the up and down arrow buttons.
Limited Override (Keyboard Locked): When the keyboard is locked (switch #2 ON), users can temporarily override the temperature setpoint for 1 hour. This is achieved by pressing either the up or down arrow button. The override range is ±6°F or ±3°C from the programmed daytime setpoint.
General Information Display: The thermostat normally displays room temperature, the current mode of operation, and whether heating is active.
Power Failure Resilience: A key feature of this thermostat is its ability to retain selected setpoints even during power losses of any duration. It does not require a battery for memory retention. When power is restored, the thermostat resumes operation as if no power interruption occurred.
Temperature Accuracy: For full temperature accuracy, the thermostat must be installed and powered for at least one hour.
Installation: The thermostat should be mounted on an inside wall in a frequently occupied area, at least 18" (46cm) from any outside wall, and approximately 5' (1.5m) above the floor, in a location with freely circulating air at an average temperature.
Locations to Avoid for Installation:
Mounting Procedure:
Replacing the Thermostat on the Subbase:
Warranty: The manufacturer provides a limited two-year warranty to the original purchaser, covering defects in workmanship and materials. Free replacement will be provided by the dealer upon proof of purchase.
Exclusions from Warranty: The warranty does not cover misuse, abuse, unauthorized alterations, or repairs. The manufacturer is not liable for consequential damages, including those resulting from defects, loss of use, or misuse.
FCC Compliance: This equipment complies with the limits for a Class B computing device pursuant to Subpart J of Part 15 of FCC rules, provided it is installed in strict accordance with the manufacturer's instructions.