- 18 -
1) Remove the cover on the tip of the DC cord plug by turning it
counterclockwise.
2) When removing the cover, also remove the head terminal and
the fuse.
3) Pull out the fuse from the head terminal.
4) Replaced the fuse with a new one after making sure that its
polarity direction is correct (fig.5). Always use the special thermal
fuse supplied through Engel dealer. The arrow printed on the
fuse shall point to the head terminal as shown in figure 5 below.
5) Re-assemble the DC cord plug in a reverse order of disassembly
and tighten the cover firmly.
6) Check whether the refrigerator runs normally. If you encounter
any further trouble, please contact an authorized ENGEL service
agent near you.
Do not use conventional glass tube fuses. Use only those
designed exclusively for ENGEL refrigerator and distributed
through its dealers.