EasyManua.ls Logo

ENSONIQ Mirage - Page 3

ENSONIQ Mirage
9 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Servicing
the
Mirage
is
quite
simple
and
straightforward.
Rather
than
diagnose
and
replace
individual
components,
you
will
replace
complete
modules.
The
Ensoniq
Module
Exchange
Program
is
available
to
all
Authorized
Repair
Stations
and
will
be
the
most
cost
and
time
efficient
method
for
both
you and
your
customer.
At
Ensoniq
we
are
equipped
with
sophisticated
machinery
to
diagnose
module
faults
quickly
and
accurately.
The
exchange
program
will
help
you
to
make
reliable
repairs
to
your
customers’
instruments
with
a
minimum
of
downtime
and
expense.
The
troubleshooting
chart
will
cover
just
about
any
occurrence
and
will
tell
you
which
module
should
be
replaced.
Refer
to
the
appropriate
section
for
the
steps
involved
in
the
replacement
of
the
particular
module.
TROUBLESHOOTING
THE
MIRAGE
Most
problems
with
the
Mirage
will
be
fairly
easy
to
diagnose,
with
a
few
exceptions.
What
may
appear
to
be
disk
drive
or
display
problems
are
often
problems
with
the
power
supply
or
with
a
defective
diskette.
For
this
reason,
we
recommend
that
you
always
load
a
diskette
that
you
know
is
good
and
check
the
power
supply
before
troubleshooting
the
rest
of
the
unit.
TO
CHECK
THE
POWER
SUPPLY
First,
plug
the
Mirage
in
and
turn
it
on.
Then
remove
the
five
screws
securing
the
control
panel
and
raise
the
panel.
Check
to
make
sure
that
all
the
connections
are
secure
and
correct.
When
the
Mirage
has
warmed
up
for
five
minutes
begin
to
test
the
voltages
at
the
points
shown
in
Figure
2
and
Figure
3A
-
3B.
If
the
voltages
vary
outside
the
allowable
limits,
replace
the
power
supply
and
test
the
unit
before
proceeding
with
further
diagnosis.
TRANSFORMER
AND
POWER
SUPPLY
VOLTAGE
CHECK
POINTS
The
following
charts
show
the
connector
terminal
number
and
correct
voltage
values
for
the
power
supply
and
transformer.
POWER
SUPPLY
VOLTAGE
MEASUREMENTS
MEASURE
BETWEEN
VOLTAGE
VALUE
TERMINAL
NO.'S
REAR
OF
UNIT
f
N
A
+5VDC
+5%
(SOmv
AC
ripple
max.)
TO
HARNESS
+12VDC
+10%
POWER
SUPPLY
BOARD
(100mv
AC
ripple
max.)
L
TO
HARNESS
Ба
-12VDC
+10%
TO
TRANSFORMER
(100mv
AC
ripple
max.)
FIGURE
2
-
POWER
SUPPLY
VOLTAGE
CHECK
POINTS
ISVAC
+20%
24VAC
+20%
AC
LINE
VOLTAGE
MEASUREMENTS
REAR
OF
UNIT
t
With
the
power
switch
OFF,
120VAC
should
measure
from:
ІА
-
2A
2A
-
2B
3A
-
3B
FUSE
BOTTOM
HOLDER
FIGURE
3A
IS
INCORRECT
Refer
to
Service
Bulletin
#5
for
AC
Line
Voltage
Check
Points
With
the
power
switch
ON,
120VAC
should
measure
from:
|
i
T
1A
-
2B
SMALL
CONNECTOR
|
ІВ
-
2B
2B
-
3A
NOTE:
LOAD
SIDE
MUST
BE
FUSED
2B
-
3B
There
should
be
no
voltage
across
the
power
switch
contacts
(3A
-
3B).
WIRE
WITH
LARGE
CONNECTOR
FIGURE
ЗА
AC
LINE
VOLTAGE
CHECK
POINTS
WIRING
FOR
EARLY
MODEL
CASE
(WHERE
TRANSFORMER
IS
ON
THE
LEFT).